Nitrogen |
 |
|
Home
| Contact us | Feedback |
|
|
|
| |
|
|
|
 |
Products |
|
|
|
|
Compressed Air & Gas Drying Systems
 |
|
 |
|
Heatless Type | Heat of Compression Type (HOC) |
Internal Heater Type (IHD)
Blower Heat Regenerated Type (BRD)
|
Split Flow-No Purge Loss Type (SFD)
Refrigerated Type | Custom Made |
|
|
Heat of Compression Type (HOC) |
Heat of Compression type air
dryer is a breakthrough in Drying technology. The hot air
from the Compressor at 120°C and higher temp, is used
directly for regeneration of the desiccant. After
regeneration, this air is cooled down to 40°C and then it is
dried in second tower. Thus the use of heaters is
eliminated. For eg. in the 6+6 Hrs. Cycle the hot air is fed
for regeneration for 4 Hrs. and for balance 2 Hr. a
changeover takes place where the air is first cooled in
cooler, then dried and before going to the outlet, cools the
regenerated desiccant bed, thus bringing it down to ambient
temperature. This cycle is reversed for the next 4Hrs. where
the Adsorber drying the air in the previous cycle goes for
regeneration and vice versa.
|
 |
There is considerable power saving in this type of Air
Dryers and the dew point is also better than the
Refrigerated type of Dryers whereas, the power consumption
is almost negligible.
|
|
SPECIFICATIONS FOR HEAT OF COMPRESSION TYPE AIR DRYER |
|
MODEL NO. |
CAPACITY |
PIPE LINE SIZE
mm |
COOLING WATER REQT.
LPM |
APROX. OVERRALL DIMENSIONS |
|
M³/ HR |
CFM |
LENGHT
mm |
WIDTH
mm |
HEIGHT
mm |
|
ANHCD-01 |
81.5 |
50 |
25 |
12 |
1400 |
1200 |
1800 |
|
ANHCD-02 |
122.7 |
75 |
25 |
18 |
1500 |
1200 |
1800 |
|
ANHCD-03 |
163.0 |
100 |
25 |
24 |
1600 |
1400 |
1800 |
|
ANHCD-04 |
244.5 |
150 |
40 |
36 |
1800 |
1500 |
2000 |
|
ANHCD-05 |
326.0 |
200 |
40 |
48 |
1800 |
1500 |
2000 |
|
ANHCD-06 |
489.0 |
300 |
50 |
72 |
2000 |
1500 |
2200 |
|
ANHCD-07 |
652.0 |
400 |
50 |
96 |
2000 |
1500 |
2200 |
|
ANHCD-08 |
815.0 |
500 |
65 |
120 |
2000 |
1800 |
2200 |
|
ANHCD-09 |
978.0 |
600 |
65 |
144 |
2200 |
1800 |
2400 |
|
ANHCD-10 |
1222.0 |
750 |
80 |
180 |
2400 |
1800 |
2400 |
|
ANHCD-11 |
1630.0 |
1000 |
80 |
240 |
2500 |
2000 |
2600 |
|
ANHCD-12 |
2037.0 |
1250 |
100 |
300 |
2500 |
2000 |
2800 |
|
ANHCD-13 |
2445 |
1500 |
100 |
360 |
2500 |
2000 |
3000 |
|
ANHCD-15 |
3260.0 |
2000 |
125 |
480 |
3000 |
2000 |
3000 |
|
ANHCD-16 |
4075.0 |
2500 |
125 |
600 |
3000 |
2000 |
3400 |
|
|
[
Top ] |
|
[ FOR VIEWING THE SCHEMATIC DRAWING ] |
|
The above capacities are
rated at an inlet temp. of 40°C.,
7kg/ Cm2 Pr. and at
an outlet dew point of (-) 40°C.
at Atm. Pressure, Supply Voltage of 220 V-1 PH- 50 HZ or
415V-3PH-50 Hz.
Above data is only for estimation and can be changed without
notice. For special systems and higher capacities contact
us. |
|
[
Top ] |
|
|
|
 |
|
Copyright © 1995 Airox Nigen Equipments Pvt. Ltd. |
|
|
|